Japan's Information-technology Promotion Agency (IPA) published an alert on November 24, 2026 (JST) about an authentication bypass vulnerability (CVE-2026-123890) in Broadcom's virtualization management software, VMware vCenter Server (vCenter). Because attackers are already exploiting the flaw, the agency is urging users to apply the security fixes.

Attackers Can Gain Administrator Access Over the Network Without Credentials

The vulnerability lies in the authentication handling of the VMware Directory Service component in vCenter. According to Broadcom's security advisory VMSA-2026-0009, published on November 19, an attacker with network access to vCenter can bypass authentication and gain unauthorized access to the system. Broadcom rates it 9.8 under CVSSv3, placing it in the highest "Critical" severity tier.

In an analysis published on November 20, Google Threat Intelligence Group (GTIG) and Mandiant said the flaw can be exploited through the RPC interface used by vCenter's single sign-on (SSO) service on port 2012, giving the attacker a session as vSphere's top-level administrator account. Broadcom has not provided a workaround, so installing a fixed version is the only remedy.

Fixes Cover Four Release Lines, While 7.0 Customers Must Contact Support

The fixed versions available at the time of writing are listed below.

AffectedFixed version
vCenter 9.1.x (VMware Cloud Foundation / vSphere Foundation)9.1.1.0200
vCenter 9.0.x (same as above)9.0.2.0200
vCenter 8.08.0 U3m
vCenter in VMware Cloud Foundation 5.x5.2.5
vCenter 7.0Customers with extended support contracts should contact Broadcom Support
VMware Telco Cloud Platform / Telco Cloud InfrastructureSee Broadcom knowledge base article KB463116

The 7.0 line is the one to watch. No fixed build number has been published, and customers with extended support contracts are told to contact Broadcom Support. The IPA alert also notes that 7.0 is affected, as are the vCenter components of Broadcom's telecom-oriented products, and asks users to check the vendor's information for details.

VMSA-2026-0009 also covers four other vulnerabilities, including a SQL injection flaw in SDDC Manager (CVE-2026-123891), rated between 6.7 and 8.1 under CVSSv3. The IPA alert focuses only on CVE-2026-123890.

A Suspected China-Linked Actor Has Exploited It Since September

According to GTIG, the vulnerability was exploited by a threat group it calls ARMORY CASTLE, previously tracked as UNC5221, which GTIG suspects is a China-nexus espionage actor. Forensic evidence shows the exploitation dates back to early September 2026.

GTIG says the attackers used a tool called BONESAW to take over vCenter and create an SSO administrator account. They then extracted the SAML token signing key to forge credentials, bypassed multi-factor authentication, and went through ESXi hosts to pull credential files from virtual machine disks. The initial entry point was a zero-day vulnerability in a BeyondTrust remote support product.

The U.S. Cybersecurity and Infrastructure Security Agency (CISA) added the vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog on November 20 (U.S. time). The IPA alert follows that development and calls on users in Japan to respond.

Organizations Running vCenter Need to Update Promptly

vCenter is the core software for centrally managing large numbers of virtual machines and ESXi hosts, so a compromise can affect the entire virtual environment beneath it. IPA asks users to apply the fixes following the procedures published by the vendor.

GTIG and Mandiant also strongly recommend applying the fixes immediately. They point to the VCSA Hardening & Logging Tool, which restricts traffic to vCenter to the ports that are needed and forwards logs to an external system, while cautioning that thorough testing and change control are needed before deploying it in production.

Our Take

What stands out here is that the flaw was exploited for more than two months before it was disclosed. Even after patching, an organization that was breached earlier may still have attacker-created accounts or stolen keys in place. That said, not every organization was hit, and the confirmed activity comes from a specific threat actor. Still, if vCenter or port 2012 is reachable from a broad network, it would be prudent to check for unfamiliar SSO accounts at the same time as updating.

Summary

An authentication bypass vulnerability in vCenter (CVE-2026-123890) has been used in real attacks, and IPA has called on users to apply the fixed versions. The alert is aimed at administrators at companies and organizations that run vCenter or VMware Cloud Foundation. IPA says it will update its page if there is more to add, so it is worth keeping an eye on further information, including how the 7.0 line will be handled.